Our Products
PHOTOVOLTAIC EQUIPMENT
![]() |
FAC3: INSULATION MONITORING DEVICE WITH AUTOMATIC RESETThe FAC3 detects insulation failure to ground, discriminating whether the failure is positive or negative. Reset function incorporated with selectable time. It has two output contacts, potential-free changeover. Suitable for application in photovoltaic installations up to 1000 Vdc. |
MORE INFORMATION | ||
![]() |
FAC/055 INSULATION MONITOR FOR BATTERIE'S INSTALATIONSDetected in installations of 24 VDC or 48 VDC, lack of insulation of the leads (+) or (-) to ground. The same model is valid for both installations (24/48 VDC) |
MORE INFORMATION | ||
![]() |
FAT MONITOR THAT DETECTS EARTH LEAKAGE IN PHOTOVOLTAIC INSTALLATIONS WITH A GROUNDED POLE
This FAT equipment measures the flow of current to ground and when it reaches a certain level, it acts, and the union to ground will be open. That way if someone accidentally touches the pole is not connected to ground, it opens the circuit.
|
MORE INFORMATION | ||
![]() |
FAT-H: MONITORING EARTH LEAKAGE IN PHOTOVOLTAIC INSTALLATIONS IN WHICH ONE POLE IS GROUNDEDThis FAT-H device measures the current to ground and when it reaches a certain level acts giving orders via a contact potential-free. This contact may be used to disconnect the connection to ground, stopping the inverter voltage or short-circuit the panels, it depend of the associated equipment used. |
MORE INFORMATION | ||
![]() |
THE MED - MEASURE THE VOLTAGE AND CURRENT OF A PHOTOVOLTAIC. WITH COMUNICATIONS.RS485The MED allows remote monitoring operation of the installation. Use the MODBUS-RTU protocol. |
MORE INFORMATION | ||
![]() |
MED5: MEASUREMENT OF CURRENTS IN FOTOVIVO INST. WITH INTERFACE RS-485The MED5 is a device designed to measure the intensities of up to five branches of a photovoltaic system, sending this information to the control center via communications. |
MORE INFORMATION | ||
![]() |
PRMEDC: DC MEASURING TRANSDUCERSIn photovoltaic systems, convert levels of input voltage or current levels to output current type (4-20mA, 0-5mA, 0-20mA). The input, output and auxiliary supply are galvanically isolated from each other |
MORE INFORMATION | ||
![]() |
BSF5: TRACKER FAULT DETECTORThe BSF5 is used in photovoltaic installations containing several trackers or strings. Together with the NINFAC DC Breakers, it determines which tracker has an isolation fault once it has been detected by the installation's Isolation Monitoring Device. |
MORE INFORMATION | ||
![]() |
NINFAC - BREAKER DCUpon receiving the order from a monitor of isolation (for example, FAC3 / I), the NINFAC disconnects the inverter from solar panels, then power panels shorted and grounded. |
|||
![]() |
NMI - INTEGRATED MODULE: MONITOR ISOLATION AND BREAKERIncluded in the same set a Monitor of Isolation FAC3 and Continuous Switch NINFAC |
|||
![]() |
NIPS- DC BREAKER 300AIn the event of insulation failure, the NIPS disconnects the PV panels to the inverter, and shorted it to earth. |
MORE INFORMATION | ||
![]() |
FACV INSULATION MONITORING ACThe FACV monitors the insulation resistance AC power circuits unearthed (IT systems) from 0 to 320 AC. |
MORE INFORMATION | ||
![]() |
MED6I1V MEASURE THE VOLTAGE AND CURRENTEquipment for measuring up to 6 intensities and 1 DC voltage of 1,000 V. The current measurement is done through hall effect module external to the equipment, the range is 25 to 800 amperes.
|
|||
|
||||